Multi-factor authentication
Working humidity
Access Controller
- Supports 2 door control. It can extend up to 62 DS-K2M002X access modules, and up to 126 doors can be controlled
- Downstream RS-485 redundancy wiring design to ensure communication stability. 5-ch downlink RS-485 interface supports two applications: 1. When 4-ch RS-485 communication, the 5th RS-485 can be used as a redundant application; 2. 4-ch RS-485 forms 2 groups of dual-bus loops with physical isolation. It is recommended that you do not have more than 16 access modules attached to each loop bus.
- Web configuration management. All configurations can be realized via web without software application
- Supports professional access control applications such as multi-door interlocking and anti-passback
- Supports backup battery access. Charging and discharging are available
- It has status indicators such as power supply, communication and operation, which is convenient for equipment health detection
- Powers supply by PoE, and Wi-Fi is available
System |
|
Operating system
| Linux
|
Network
|
|
Wired network
| 1, 10/100/1000 Mbps self-adaptive
|
Wi-Fi
| Support, 2.4 G, 802.11b/g/n
|
Interface
|
|
Network interface
| 1 |
Lock control
| 2 |
Exit button
| 2 |
Door contact input
| 2 |
Alarm input
| 4 |
Alarm output
| 4 |
TAMPER | 1 |
RS-485
| 7, 2 for card reader, 5 for access modules (4 for communication, each interface can connect up to 16 access modules; 1 for redundancy)
|
Wiegand | 4, standard 26/34 input, supports custom Wiegand settings
|
USB
| 1, USB 2.0
|
PoE | 1 |
Fire interface
| 1 |
Capacity
|
|
User capacity
| 100,000
|
Fingerprint capacity
| 100,000
|
Card capacity
| 200,000
|
Event capacity
| 600,000 |
Linked door capacity
| Self: 2 doors Extended: up to 126 doors (connected with 62 access modules)
|
Linked card reader capaciry
| 4 RS-485 card readers (OSDP protocol) and 4 Wiegand card readers
|
Authentication |
|
Fingerprint recognition duration
| < 1 s
|
General
|
|
Indicator
| 11 indicators, 1 for indicating power status, 1 for running status, 1 for wired network status, 1 for Wi-Fi status, 5 for RS-485 status, and 2 for door status
|
Battery | Charge and discharge
|
Power supply
| 12 ± 15% VDC, standard PoE
|
Power consumption
| ≤ 72 W
|
Working temperature
| -10 °C to 55 °C (14 °F to 131 ° F)
|
Working humidity
| 0% to 90% (No condensing)
|
Installation
| Installation with guide rail
|
Language
| English, Thai, Traditional Chinese, Indonesian, Vietnamese, Arabic, Spanish (Europe), Spanish (South America), Italian, French, Dutch, Russian, Ukrainian, Portuguese (Europe), Portuguese (Brazil), Serbian, Croatian, Bulgarian, German, Greek, Romanian
|
Function
| Support
|
Configuration via Web browser
| Support
|
Multi-factor authentication
| Support
|
First person in
| Support
|
Anti-passback
| Support 32 routes (64 card readers each)
|
Multi-door interlocking
| Support 32 groups (32 doors each) |
DATA SHEET | |